{"_buckets": {"deposit": "dfcf23e1-44f9-48c2-8c17-068d26d2b5a1"}, "_deposit": {"id": "26522", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "26522"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00026522", "sets": ["1725", "1088"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "113", "bibliographicPageStart": "108", "bibliographicVolumeNumber": "202", "bibliographic_titles": [{"bibliographic_title": "Journal of power sources"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "石田, 政義"}], "nameIdentifiers": [{"nameIdentifier": "559", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30272173", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000030272173"}, {"nameIdentifier": "0000001046", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000001046"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Polymer electrolyte-based unitized reversible fuel cells (URFCs) can be operated either as an electrolyzer to split water into hydrogen and oxygen using electric power or as a fuel cell to supply electric power when fed hydrogen and oxygen or air. In a URFC, titanium (Ti)-felt is used as a gas diffusion layer (GDL) in the oxygen electrode and typical carbon paper is used as a GDL in the hydrogen electrode. Here, first, Ti-powder was loaded into the Ti-felt GDL in URFCs to produce an effective pore distribution for water management in the membrane. Then, the effect of this Ti-powder loading on the cell performance was examined for both fuel cell and electrolysis operations. Experimental results revealed that the Ti-powder loading significantly improved the fuel cell performance under fully humidified conditions (relative humidity (RH) = 100%), but not under relatively dry conditions (RH = 66%). In contrast, the Ti-powder loading had no effect on the electrolysis performance.", "subitem_description_type": "Abstract"}]}, "item_5_identifier_34": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2241/115896"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V."}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.jpowsour.2011.11.041", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2011 Elsevier B.V. NOTICE: this is the author’s version of a work that was accepted for publication in Journal of power sources. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, VOL202 , 2012, DOI:10.1016/j.jpowsour.2011.11.041"}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0378-7753", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00705373", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "情報学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Hwang, Chul Min"}], "nameIdentifiers": [{"nameIdentifier": "91428", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishida, Masayoshi"}], "nameIdentifiers": [{"nameIdentifier": "91429", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ito, Hiroshi"}], "nameIdentifiers": [{"nameIdentifier": "91430", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Maeda, Tetsuhiko"}], "nameIdentifiers": [{"nameIdentifier": "91431", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakano, Akihiro"}], "nameIdentifiers": [{"nameIdentifier": "91432", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kato, Atsushi"}], "nameIdentifiers": [{"nameIdentifier": "91433", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshida, Tetsuya"}], "nameIdentifiers": [{"nameIdentifier": "91434", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2013-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JPS_202.pdf", "filesize": [{"value": "692.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 692300.0, "url": {"label": "JPS_202.pdf", "url": "https://tsukuba.repo.nii.ac.jp/record/26522/files/JPS_202.pdf"}, "version_id": "7df7d6cd-f381-4523-85e4-c92a942b3786"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Effect of titanium powder loading in gas diffusion layer of a polymer electrolyte unitized reversible fuel cell", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Effect of titanium powder loading in gas diffusion layer of a polymer electrolyte unitized reversible fuel cell"}]}, "item_type_id": "5", "owner": "1", "path": ["1725", "1088"], "permalink_uri": "http://hdl.handle.net/2241/115896", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-03-13"}, "publish_date": "2012-03-13", "publish_status": "0", "recid": "26522", "relation": {}, "relation_version_is_last": true, "title": ["Effect of titanium powder loading in gas diffusion layer of a polymer electrolyte unitized reversible fuel cell"], "weko_shared_id": 5}
Effect of titanium powder loading in gas diffusion layer of a polymer electrolyte unitized reversible fuel cell
http://hdl.handle.net/2241/115896
http://hdl.handle.net/2241/11589601bda4be-50c0-4d97-9e86-83f615dc387b
名前 / ファイル | ライセンス | アクション |
---|---|---|
JPS_202.pdf (692.3 kB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-03-13 | |||||
タイトル | ||||||
タイトル | Effect of titanium powder loading in gas diffusion layer of a polymer electrolyte unitized reversible fuel cell | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Hwang, Chul Min
× Hwang, Chul Min× Ishida, Masayoshi× Ito, Hiroshi× Maeda, Tetsuhiko× Nakano, Akihiro× Kato, Atsushi× Yoshida, Tetsuya |
|||||
著者別名 |
石田, 政義
× 石田, 政義 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Polymer electrolyte-based unitized reversible fuel cells (URFCs) can be operated either as an electrolyzer to split water into hydrogen and oxygen using electric power or as a fuel cell to supply electric power when fed hydrogen and oxygen or air. In a URFC, titanium (Ti)-felt is used as a gas diffusion layer (GDL) in the oxygen electrode and typical carbon paper is used as a GDL in the hydrogen electrode. Here, first, Ti-powder was loaded into the Ti-felt GDL in URFCs to produce an effective pore distribution for water management in the membrane. Then, the effect of this Ti-powder loading on the cell performance was examined for both fuel cell and electrolysis operations. Experimental results revealed that the Ti-powder loading significantly improved the fuel cell performance under fully humidified conditions (relative humidity (RH) = 100%), but not under relatively dry conditions (RH = 66%). In contrast, the Ti-powder loading had no effect on the electrolysis performance. | |||||
書誌情報 |
Journal of power sources 巻 202, p. 108-113, 発行日 2012-03 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0378-7753 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00705373 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.jpowsour.2011.11.041 | |||||
権利 | ||||||
権利情報 | © 2011 Elsevier B.V. NOTICE: this is the author’s version of a work that was accepted for publication in Journal of power sources. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, VOL202 , 2012, DOI:10.1016/j.jpowsour.2011.11.041 | |||||
著者版フラグ | ||||||
値 | author | |||||
出版者 | ||||||
出版者 | Elsevier B.V. | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2241/115896 | |||||
識別子タイプ | HDL |