{"created":"2021-03-01T07:19:02.008791+00:00","id":39723,"links":{},"metadata":{"_buckets":{"deposit":"bc75bfd4-68fc-4a71-aca0-9b26f6429431"},"_deposit":{"id":"39723","owners":[],"pid":{"revision_id":0,"type":"depid","value":"39723"},"status":"published"},"_oai":{"id":"oai:tsukuba.repo.nii.ac.jp:00039723","sets":["117:142","3:62:5595:5396"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"404","bibliographicPageStart":"395","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"Magnetic resonance in medical sciences"}]}]},"item_5_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"巨瀬, 勝美"}],"nameIdentifiers":[{}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Echo-planar imaging (EPI) sequences were developed for a 9.4 Tesla vertical standard bore (~54 mm) superconducting magnet using an unshielded gradient coil optimized for live mice imaging and a data correction technique with reference scans. Because EPI requires fast switching of intense magnetic field gradients, eddy currents were induced in the surrounding metallic materials, e.g., the room temperature bore, and this produced serious artifacts on the EPI images. We solved the problem using an unshielded gradient coil set of proper size (outer diameter = 39 mm, inner diameter = 32 mm) with time control of the current rise and reference scans. The obtained EPI images of a phantom and a plant sample were almost artifact-free and demonstrated the promise of our approach.\n","subitem_description_type":"Abstract"}]},"item_5_publisher_27":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Japanese Society Magnetic Resonance in Medicine"}]},"item_5_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2463/mrms.tn.2015-0123","subitem_relation_type_select":"DOI"}}]},"item_5_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2016 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution- NonCommercial-NoDerivatives International License."}]},"item_5_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1347-3182","subitem_source_identifier_type":"ISSN"}]},"item_5_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11648770","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"KODAMA, Nao"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KOSE, Katsumi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-17"}],"displaytype":"detail","filename":"MRMS_15-4-395.pdf","filesize":[{"value":"3.0 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"MRMS_15-4-395","url":"https://tsukuba.repo.nii.ac.jp/record/39723/files/MRMS_15-4-395.pdf"},"version_id":"aaa6aaba-3053-4a8d-b914-3687ae16891e"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil"}]},"item_type_id":"5","owner":"1","path":["142","5396"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-11-17"},"publish_date":"2016-11-17","publish_status":"0","recid":"39723","relation_version_is_last":true,"title":["Echo-Planar Imaging for a 9.4 Tesla Vertical-Bore Superconducting Magnet Using an Unshielded Gradient Coil"],"weko_creator_id":"1","weko_shared_id":5},"updated":"2022-04-27T09:09:58.031076+00:00"}