{"created":"2021-03-01T07:18:04.143407+00:00","id":38840,"links":{},"metadata":{"_buckets":{"deposit":"22803c42-ea75-4d63-8ea8-f1add5059e10"},"_deposit":{"id":"38840","owners":[],"pid":{"revision_id":0,"type":"depid","value":"38840"},"status":"published"},"_oai":{"id":"oai:tsukuba.repo.nii.ac.jp:00038840","sets":["2780:1995","2780:4952","2780:956","3:62:5592:3037"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"1054","bibliographicPageStart":"1050","bibliographicVolumeNumber":"28","bibliographic_titles":[{"bibliographic_title":"Journal of physical therapy science"}]}]},"item_5_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鎌田, 浩史"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"坂根, 正孝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山崎, 正志"}],"nameIdentifiers":[{},{},{}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"[Purpose] Lower-limb deep vein thrombosis is a complication of orthopedic surgery. A leg-exercise apparatus named “LEX” was developed as a novel active-exercise apparatus for deep vein thrombosis prevention. Muscle activity was evaluated to assess the effectiveness of exercise with LEX in the prevention. [Subjects] Eight healthy volunteers participated in this study. [Methods] Muscle activities were determined through electromyography during exercise with LEX [LEX (+)] and during active ankle movements [LEX (−)]. The end points were peak % maximum voluntary contraction and % integrated electromyogram of rectus femoris, vastus lateralis, biceps femoris, tibialis anterior, gastrocnemius, and soleus. [Results] LEX (+) resulted in higher average values in all muscles except the tibialis anterior. Significant differences were noted in the peak of the biceps femoris and gastrocnemius and in the integrated electromyogram of the rectus femoris, vastus lateralis, gastrocnemius, and soleus. The LEX (+)/LEX (−) ratio of the peak was 2.2 for the biceps femoris and 2.0 for the gastrocnemius . The integrated electromyogram was 1.8 for the gastrocnemius, 1.5 for the rectus femoris, 1.4 for the vastus lateralis, and 1.2 for the soleus. [Conclusion] Higher muscle activity was observed with LEX (+). LEX might be a good tool for increasing lower-limb blood flow and deep vein thrombosis prevention.","subitem_description_type":"Abstract"}]},"item_5_publisher_27":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Society of Physical Therapy Science"}]},"item_5_publisher_28":{"attribute_name":"出版者別名","attribute_value_mlt":[{"subitem_publisher":"理学療法科学学会"}]},"item_5_relation_10":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"27134410","subitem_relation_type_select":"PMID"}}]},"item_5_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1589/jpts.28.1050","subitem_relation_type_select":"DOI"}}]},"item_5_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"©2016 The Society of Physical Therapy Science. Published by IPEC Inc."},{"subitem_rights":"This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License ."}]},"item_5_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0915-5287","subitem_source_identifier_type":"ISSN"}]},"item_5_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA10798949","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Tanaka, Kenta"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kamada, Hiroshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shimizu, Yukiyo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Aikawa, Shizu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Irie, Shun"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Ochiai, Naoyuki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Sakane, Masataka"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yamazaki, Masashi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-08-03"}],"displaytype":"detail","filename":"JPTS_28-3.pdf","filesize":[{"value":"817.2 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"JPTS_28-3","url":"https://tsukuba.repo.nii.ac.jp/record/38840/files/JPTS_28-3.pdf"},"version_id":"24bffc8d-1ab7-4b35-8950-0c8b38daa54c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Muscle activity in the lower limbs during push-down movement with a new active-exercise apparatus for the leg","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Muscle activity in the lower limbs during push-down movement with a new active-exercise apparatus for the leg"}]},"item_type_id":"5","owner":"1","path":["1995","956","4952","3037"],"pubdate":{"attribute_name":"公開日","attribute_value":"2016-08-03"},"publish_date":"2016-08-03","publish_status":"0","recid":"38840","relation_version_is_last":true,"title":["Muscle activity in the lower limbs during push-down movement with a new active-exercise apparatus for the leg"],"weko_creator_id":"1","weko_shared_id":5},"updated":"2022-04-27T09:53:44.246677+00:00"}