{"created":"2021-03-01T07:07:48.831082+00:00","id":29333,"links":{},"metadata":{"_buckets":{"deposit":"f1c4eb72-5092-4c05-99c1-795b2b19ef10"},"_deposit":{"id":"29333","owners":[],"pid":{"revision_id":0,"type":"depid","value":"29333"},"status":"published"},"_oai":{"id":"oai:tsukuba.repo.nii.ac.jp:00029333","sets":["2780:493","3:62:5296:374"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"21","bibliographicPageEnd":"5151","bibliographicPageStart":"5143","bibliographicVolumeNumber":"52","bibliographic_titles":[{"bibliographic_title":"Applied optics"}]}]},"item_5_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"安野, 嘉晃"}],"nameIdentifiers":[{},{},{}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"We propose a single-step method appropriated for a fiber-optic probe-based full-range spectral domain optical coherence tomography (OCT). The fiber-optic probe was scanned over a sample with a magnetically driven actuator. In the reference arm, a phase shift of π/2 was applied during two neighbor axial scanning, from which the complex spectral interferogram was directly reconstructed. Since the complex-conjugate-free OCT image is obtained by doing just one Fourier transform on the complex interferogram, obtaining the full-range image is simple in algorithm and effective in computation time. Some full-range images of biological samples created with the proposed method are presented and the processing time is analyzed.","subitem_description_type":"Abstract"}]},"item_5_identifier_34":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2241/119665"}]},"item_5_publisher_27":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Optical Society of America"}]},"item_5_relation_10":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"23872759","subitem_relation_type_select":"PMID"}}]},"item_5_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1364/AO.52.005143","subitem_relation_type_select":"DOI"}}]},"item_5_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2013 Optical Society of America. This paper was published in Applied optics and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website:http://www.opticsinfobase.org/ao/abstract.cfm?uri=ao-52-21-5143. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law."}]},"item_5_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1559-128X","subitem_source_identifier_type":"ISSN"}]},"item_5_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00543409","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Min, Eun Jung"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Shin, Jun Geun"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Lee, Jae Hwi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Yasuno, Yoshiaki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Lee, Byeong Ha"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-12-25"}],"displaytype":"detail","filename":"AO_52-21.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AO_52-21.pdf","url":"https://tsukuba.repo.nii.ac.jp/record/29333/files/AO_52-21.pdf"},"version_id":"7f913c23-5e22-4dbe-bd3b-d0a4fa1ddfed"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Single-step method for fiber-optic probe-based full-range spectral domain optical coherence tomography","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Single-step method for fiber-optic probe-based full-range spectral domain optical coherence tomography"}]},"item_type_id":"5","owner":"1","path":["493","374"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-09-09"},"publish_date":"2013-09-09","publish_status":"0","recid":"29333","relation_version_is_last":true,"title":["Single-step method for fiber-optic probe-based full-range spectral domain optical coherence tomography"],"weko_creator_id":"1","weko_shared_id":5},"updated":"2022-04-27T08:57:46.264078+00:00"}