{"_buckets": {"deposit": "977ca232-33e4-47e1-a177-7240fe562125"}, "_deposit": {"id": "29263", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "29263"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00029263", "sets": ["1934", "2017"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013-06", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "162", "bibliographicPageStart": "156", "bibliographicVolumeNumber": "419", "bibliographic_titles": [{"bibliographic_title": "Chemical physics"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "加納, 英明"}], "nameIdentifiers": [{"nameIdentifier": "637", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "70334240", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000070334240"}, {"nameIdentifier": "0000003176", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000003176"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed a three-pulse non-degenerate multiplex coherent Raman microspectroscopic system using a white-light laser source. The fundamental output (1064 nm) of a Nd:YAG laser is used for the pump radiation with the white-light laser output (1100–1700 nm) for the Stokes radiation to achieve broadband multiplex excitations of vibrational coherences. The second harmonic (532 nm) of the same Nd:YAG laser is used for the probe radiation. Thanks to the large wavelength difference between the pump and probe radiations, coherent anti-Stokes Raman scattering (CARS) and coherent Stokes Raman scattering (CSRS) can be detected simultaneously. Simultaneous detection of CARS and CSRS enables us to obtain information on the electronic resonance effect that affects differently the CARS and CSRS signals. Simultaneous analysis of the CARS and CSRS signals provides us the imaginary part of χ(3) without introducing any arbitrary parameter in the maximum entropy method (MEM).", "subitem_description_type": "Abstract"}]}, "item_5_identifier_34": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2241/119576"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier B.V."}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.chemphys.2013.02.007", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2013 Elsevier B.V. NOTICE: this is the author’s version of a work that was accepted for publication in Chemical physics. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Chemical physics, VOL419, 2013, DOI:10.1016/j.chemphys.2013.02.007"}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0301-0104", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11523651", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "基礎工学・応用物理学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Bito, Kotatsu"}], "nameIdentifiers": [{"nameIdentifier": "101382", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okuno, Masanari"}], "nameIdentifiers": [{"nameIdentifier": "101383", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kano, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "101384", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Leproux, Philippe"}], "nameIdentifiers": [{"nameIdentifier": "101385", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Couderc, Vincent"}], "nameIdentifiers": [{"nameIdentifier": "101386", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hamaguchi, Hiro-o"}], "nameIdentifiers": [{"nameIdentifier": "101387", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2013-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "CP_419.pdf", "filesize": [{"value": "507.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 507100.0, "url": {"label": "CP_419.pdf", "url": "https://tsukuba.repo.nii.ac.jp/record/29263/files/CP_419.pdf"}, "version_id": "87a74910-abc8-435d-aad2-94510b319f29"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Three-pulse multiplex coherent anti-Stokes/Stokes Raman scattering (CARS/CSRS) microspectroscopy using a white-light laser source", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Three-pulse multiplex coherent anti-Stokes/Stokes Raman scattering (CARS/CSRS) microspectroscopy using a white-light laser source"}]}, "item_type_id": "5", "owner": "1", "path": ["1934", "2017"], "permalink_uri": "http://hdl.handle.net/2241/119576", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-08-21"}, "publish_date": "2013-08-21", "publish_status": "0", "recid": "29263", "relation": {}, "relation_version_is_last": true, "title": ["Three-pulse multiplex coherent anti-Stokes/Stokes Raman scattering (CARS/CSRS) microspectroscopy using a white-light laser source"], "weko_shared_id": 5}
Three-pulse multiplex coherent anti-Stokes/Stokes Raman scattering (CARS/CSRS) microspectroscopy using a white-light laser source
http://hdl.handle.net/2241/119576
http://hdl.handle.net/2241/119576e94d762b-3519-403d-9e30-fae37e224dd0
名前 / ファイル | ライセンス | アクション |
---|---|---|
CP_419.pdf (507.1 kB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-08-21 | |||||
タイトル | ||||||
タイトル | Three-pulse multiplex coherent anti-Stokes/Stokes Raman scattering (CARS/CSRS) microspectroscopy using a white-light laser source | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Bito, Kotatsu
× Bito, Kotatsu× Okuno, Masanari× Kano, Hideaki× Leproux, Philippe× Couderc, Vincent× Hamaguchi, Hiro-o |
|||||
著者別名 |
加納, 英明
× 加納, 英明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have developed a three-pulse non-degenerate multiplex coherent Raman microspectroscopic system using a white-light laser source. The fundamental output (1064 nm) of a Nd:YAG laser is used for the pump radiation with the white-light laser output (1100–1700 nm) for the Stokes radiation to achieve broadband multiplex excitations of vibrational coherences. The second harmonic (532 nm) of the same Nd:YAG laser is used for the probe radiation. Thanks to the large wavelength difference between the pump and probe radiations, coherent anti-Stokes Raman scattering (CARS) and coherent Stokes Raman scattering (CSRS) can be detected simultaneously. Simultaneous detection of CARS and CSRS enables us to obtain information on the electronic resonance effect that affects differently the CARS and CSRS signals. Simultaneous analysis of the CARS and CSRS signals provides us the imaginary part of χ(3) without introducing any arbitrary parameter in the maximum entropy method (MEM). | |||||
書誌情報 |
Chemical physics 巻 419, p. 156-162, 発行日 2013-06 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0301-0104 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11523651 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.chemphys.2013.02.007 | |||||
権利 | ||||||
権利情報 | © 2013 Elsevier B.V. NOTICE: this is the author’s version of a work that was accepted for publication in Chemical physics. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Chemical physics, VOL419, 2013, DOI:10.1016/j.chemphys.2013.02.007 | |||||
著者版フラグ | ||||||
値 | author | |||||
出版者 | ||||||
出版者 | Elsevier B.V. | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2241/119576 | |||||
識別子タイプ | HDL |