{"created":"2021-03-01T07:03:59.492696+00:00","id":25833,"links":{},"metadata":{"_buckets":{"deposit":"9502155d-c5ad-4d41-8023-96a8bf670647"},"_deposit":{"id":"25833","owners":[],"pid":{"revision_id":0,"type":"depid","value":"25833"},"status":"published"},"_oai":{"id":"oai:tsukuba.repo.nii.ac.jp:00025833","sets":["117:1211","117:142","3:62:5592:1625"]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"361","bibliographicPageStart":"355","bibliographicVolumeNumber":"212","bibliographic_titles":[{"bibliographic_title":"Journal of magnetic resonance"}]}]},"item_5_creator_3":{"attribute_name":"著者別名","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"寺田, 康彦"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"巨瀬, 勝美"}],"nameIdentifiers":[{}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties.","subitem_description_type":"Abstract"}]},"item_5_identifier_34":{"attribute_name":"URI","attribute_value_mlt":[{"subitem_identifier_type":"HDL","subitem_identifier_uri":"http://hdl.handle.net/2241/114743"}]},"item_5_publisher_27":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier Inc."}]},"item_5_relation_10":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"21856197","subitem_relation_type_select":"PMID"}}]},"item_5_relation_11":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.jmr.2011.07.016","subitem_relation_type_select":"DOI"}}]},"item_5_rights_12":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2011 Elsevier Inc.\n“NOTICE: this is the author's version of a work that was accepted for publication in Journal of Magnetic Resonance. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, Volume 212(2), 2011 DOI:10.1016/j.jmr.2011.07.016”"}]},"item_5_select_15":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_5_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1090-7807","subitem_source_identifier_type":"ISSN"}]},"item_5_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11113784","subitem_source_identifier_type":"NCID"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Terada, Y."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tamada, D."}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kose, K."}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-12-25"}],"displaytype":"detail","filename":"JMR_212-2.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JMR_212-2.pdf","url":"https://tsukuba.repo.nii.ac.jp/record/25833/files/JMR_212-2.pdf"},"version_id":"8d7c14b9-7386-4526-808c-96802239be0c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet"}]},"item_type_id":"5","owner":"1","path":["142","1211","1625"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-11-30"},"publish_date":"2011-11-30","publish_status":"0","recid":"25833","relation_version_is_last":true,"title":["Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet"],"weko_creator_id":"1","weko_shared_id":5},"updated":"2022-04-27T08:53:32.272748+00:00"}