{"_buckets": {"deposit": "9502155d-c5ad-4d41-8023-96a8bf670647"}, "_deposit": {"id": "25833", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "25833"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00025833", "sets": ["142", "1211", "1625"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "361", "bibliographicPageStart": "355", "bibliographicVolumeNumber": "212", "bibliographic_titles": [{"bibliographic_title": "Journal of magnetic resonance"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "寺田, 康彦"}], "nameIdentifiers": [{"nameIdentifier": "456", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20400640", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000020400640"}, {"nameIdentifier": "0000000739", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000000739"}]}, {"creatorNames": [{"creatorName": "巨瀬, 勝美"}], "nameIdentifiers": [{"nameIdentifier": "89395", "nameIdentifierScheme": "WEKO"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties.", "subitem_description_type": "Abstract"}]}, "item_5_identifier_34": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2241/114743"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier Inc."}]}, "item_5_relation_10": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "21856197", "subitem_relation_type_select": "PMID"}}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.jmr.2011.07.016", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2011 Elsevier Inc.\n“NOTICE: this is the author\u0027s version of a work that was accepted for publication in Journal of Magnetic Resonance. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, Volume 212(2), 2011 DOI:10.1016/j.jmr.2011.07.016”"}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1090-7807", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11113784", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "基礎工学・応用物理学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Terada, Y."}], "nameIdentifiers": [{"nameIdentifier": "89391", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamada, D."}], "nameIdentifiers": [{"nameIdentifier": "89392", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kose, K."}], "nameIdentifiers": [{"nameIdentifier": "89393", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2013-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "JMR_212-2.pdf", "filesize": [{"value": "1.1 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1100000.0, "url": {"label": "JMR_212-2.pdf", "url": "https://tsukuba.repo.nii.ac.jp/record/25833/files/JMR_212-2.pdf"}, "version_id": "8d7c14b9-7386-4526-808c-96802239be0c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet"}]}, "item_type_id": "5", "owner": "1", "path": ["142", "1211", "1625"], "permalink_uri": "http://hdl.handle.net/2241/114743", "pubdate": {"attribute_name": "公開日", "attribute_value": "2011-11-30"}, "publish_date": "2011-11-30", "publish_status": "0", "recid": "25833", "relation": {}, "relation_version_is_last": true, "title": ["Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet"], "weko_shared_id": 5}
Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet
http://hdl.handle.net/2241/114743
http://hdl.handle.net/2241/11474344248020-803a-4587-a4fe-31ffbdf3ffa3
名前 / ファイル | ライセンス | アクション |
---|---|---|
JMR_212-2.pdf (1.1 MB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2011-11-30 | |||||
タイトル | ||||||
タイトル | Development of a temperature-variable magnetic resonance imaging system using a 1.0 T yokeless permanent magnet | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Terada, Y.
× Terada, Y.× Tamada, D.× Kose, K. |
|||||
著者別名 |
寺田, 康彦
× 寺田, 康彦× 巨瀬, 勝美 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from −5 °C to 45 °C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties. | |||||
書誌情報 |
Journal of magnetic resonance 巻 212, 号 2, p. 355-361, 発行日 2011-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1090-7807 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11113784 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 21856197 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.jmr.2011.07.016 | |||||
権利 | ||||||
権利情報 | © 2011 Elsevier Inc. “NOTICE: this is the author's version of a work that was accepted for publication in Journal of Magnetic Resonance. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in PUBLICATION, Volume 212(2), 2011 DOI:10.1016/j.jmr.2011.07.016” |
|||||
著者版フラグ | ||||||
値 | author | |||||
出版者 | ||||||
出版者 | Elsevier Inc. | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2241/114743 | |||||
識別子タイプ | HDL |