WEKO3
アイテム
{"_buckets": {"deposit": "45583fc3-c5ea-4f09-a84a-274612dc6c46"}, "_deposit": {"id": "39089", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "39089"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00039089", "sets": ["1459", "5398", "1287", "926", "5396"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2016-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "280", "bibliographicPageStart": "273", "bibliographicVolumeNumber": "15", "bibliographic_titles": [{"bibliographic_title": "Magnetic resonance in medical sciences"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "門根, 秀樹"}], "nameIdentifiers": [{"nameIdentifier": "204163", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90599820", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000090599820"}, {"nameIdentifier": "0000000018", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000000018"}]}, {"creatorNames": [{"creatorName": "鶴嶋, 英夫"}], "nameIdentifiers": [{"nameIdentifier": "455", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "50315470", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000050315470"}, {"nameIdentifier": "0000001826", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000001826"}]}, {"creatorNames": [{"creatorName": "山海, 嘉之"}], "nameIdentifiers": [{"nameIdentifier": "204365", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "30183833", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000030183833"}, {"nameIdentifier": "0000001020", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000001020"}]}, {"creatorNames": [{"creatorName": "松村, 明"}], "nameIdentifiers": [{"nameIdentifier": "645", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "90241819", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000090241819"}, {"nameIdentifier": "0000001792", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000001792"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: Stepping motions have been often used as gait-like patterns in functional magnetic resonance imaging (fMRI) to understand gait control. However, it is still very difficult to stabilize the task-related head motion. Our main purpose is to provide characteristics of the task-related head motion during stepping to develop robust restraints toward fMRI.\nMethods: Multidirectional head and knee position during stepping were acquired using a motion capture system outside MRI room in 13 healthy participants. Six phases in a stepping motion were defined by reference to the left knee angles and the mean of superior-inferior head velocity (Vmean) in each phase was investigated. Furthermore, the correlation between the standard deviation of the knee angle (θsd) and the maximum of the head velocity (Vmax) was evaluated.\nResults: The standard deviation of each superior-inferior head position and pitch were significantly larger than the other measurements. Vmean showed a characteristic repeating pattern associated with the knee angle. Additionally, there were significant correlations between θsd and Vmax.\nConclusions: This is the first report to reveal the characteristics of the task-related head motion during stepping. Our findings are an essential step in the development of robust restraint toward fMRI during stepping task.", "subitem_description_type": "Abstract"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": " Japanese Society Magnetic Resonance in Medicine "}]}, "item_5_relation_10": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "26549164 ", "subitem_relation_type_select": "PMID"}}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2463/mrms.mp.2015-0015", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "©2015 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License."}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1347-3182", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11648770", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "医学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "SAOTOME, Kousaku"}], "nameIdentifiers": [{"nameIdentifier": "141759", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUSHITA, Akira"}], "nameIdentifiers": [{"nameIdentifier": "141760", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "NAKAI, Kei"}], "nameIdentifiers": [{"nameIdentifier": "141761", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "KADONE, Hideki"}], "nameIdentifiers": [{"nameIdentifier": "141762", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "TSURUSHIMA, Hideo"}], "nameIdentifiers": [{"nameIdentifier": "141763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SANKAI, Yoshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "141764", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUMURA, Akira"}], "nameIdentifiers": [{"nameIdentifier": "141765", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2016-09-01"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "MRMS_15-3-273.pdf", "filesize": [{"value": "967.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_9", "mimetype": "application/pdf", "size": 967100.0, "url": {"label": "MRMS_15-3-273", "url": "https://tsukuba.repo.nii.ac.jp/record/39089/files/MRMS_15-3-273.pdf"}, "version_id": "106274bb-f8bd-422c-a009-60d373066ef4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Quantitative Assessment of Head Motion toward Functional Magnetic Resonance Imaging during Stepping", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Quantitative Assessment of Head Motion toward Functional Magnetic Resonance Imaging during Stepping"}]}, "item_type_id": "5", "owner": "1", "path": ["1459", "5398", "1287", "926", "5396"], "permalink_uri": "http://hdl.handle.net/2241/00143758", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-09-01"}, "publish_date": "2016-09-01", "publish_status": "0", "recid": "39089", "relation": {}, "relation_version_is_last": true, "title": ["Quantitative Assessment of Head Motion toward Functional Magnetic Resonance Imaging during Stepping"], "weko_shared_id": 5}
Quantitative Assessment of Head Motion toward Functional Magnetic Resonance Imaging during Stepping
http://hdl.handle.net/2241/00143758
http://hdl.handle.net/2241/00143758313e5f8b-0afc-4232-b799-27132f2d6ec6
名前 / ファイル | ライセンス | アクション |
---|---|---|
MRMS_15-3-273 (967.1 kB)
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-09-01 | |||||
タイトル | ||||||
タイトル | Quantitative Assessment of Head Motion toward Functional Magnetic Resonance Imaging during Stepping | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
SAOTOME, Kousaku
× SAOTOME, Kousaku× MATSUSHITA, Akira× NAKAI, Kei× KADONE, Hideki× TSURUSHIMA, Hideo× SANKAI, Yoshiyuki× MATSUMURA, Akira |
|||||
著者別名 |
門根, 秀樹
× 門根, 秀樹× 鶴嶋, 英夫× 山海, 嘉之× 松村, 明 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Stepping motions have been often used as gait-like patterns in functional magnetic resonance imaging (fMRI) to understand gait control. However, it is still very difficult to stabilize the task-related head motion. Our main purpose is to provide characteristics of the task-related head motion during stepping to develop robust restraints toward fMRI. Methods: Multidirectional head and knee position during stepping were acquired using a motion capture system outside MRI room in 13 healthy participants. Six phases in a stepping motion were defined by reference to the left knee angles and the mean of superior-inferior head velocity (Vmean) in each phase was investigated. Furthermore, the correlation between the standard deviation of the knee angle (θsd) and the maximum of the head velocity (Vmax) was evaluated. Results: The standard deviation of each superior-inferior head position and pitch were significantly larger than the other measurements. Vmean showed a characteristic repeating pattern associated with the knee angle. Additionally, there were significant correlations between θsd and Vmax. Conclusions: This is the first report to reveal the characteristics of the task-related head motion during stepping. Our findings are an essential step in the development of robust restraint toward fMRI during stepping task. |
|||||
書誌情報 |
Magnetic resonance in medical sciences 巻 15, 号 3, p. 273-280, 発行日 2016-07 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1347-3182 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11648770 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 26549164 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2463/mrms.mp.2015-0015 | |||||
権利 | ||||||
権利情報 | ©2015 Japanese Society for Magnetic Resonance in Medicine This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives International License. | |||||
著者版フラグ | ||||||
値 | publisher | |||||
出版者 | ||||||
出版者 | Japanese Society Magnetic Resonance in Medicine |