WEKO3
アイテム
{"_buckets": {"deposit": "92b56829-0a38-457a-839e-60347b02e27f"}, "_deposit": {"id": "31416", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31416"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00031416", "sets": ["142", "602"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "9", "bibliographicPageEnd": "1912", "bibliographicPageStart": "1905", "bibliographicVolumeNumber": "33", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Medical Imaging"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "玉田, 大輝"}], "nameIdentifiers": [{"nameIdentifier": "108046", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "巨瀬, 勝美"}], "nameIdentifiers": [{"nameIdentifier": "108047", "nameIdentifierScheme": "WEKO"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A compressed sensing method using a cross sampling and self-calibrated off-resonance correction is proposed. Estimation of the magnetic field inhomogeneity based on image registration enables the off-resonance correction with no additional radio-frequency pulses or acquisitions. In addition to this advantage, a fast and straightforward calculation was achieved by using the first-order components of the magnetic field inhomogeneity. Imaging experiments using a phantom and a chemically fixed mouse demonstrated practical benefits in improving blurring and artifacts in magnetic resonance images in low field magnetic resonance imaging systems.", "subitem_description_type": "Abstract"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "IEEE"}]}, "item_5_relation_10": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "24879645", "subitem_relation_type_select": "PMID"}}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/TMI.2014.2326864", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works."}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0278-0062", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA10634023", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "基礎工学・応用物理学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tamada, D."}], "nameIdentifiers": [{"nameIdentifier": "108044", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kose, K."}], "nameIdentifiers": [{"nameIdentifier": "108045", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2014-09-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "IEEETMI_33-9.pdf", "filesize": [{"value": "537.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 537300.0, "url": {"label": "IEEETMI_33-9", "url": "https://tsukuba.repo.nii.ac.jp/record/31416/files/IEEETMI_33-9.pdf"}, "version_id": "7cf31822-8075-4eff-9d16-802a3bb422a0"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Two-Dimensional Compressed Sensing Using the Cross-sampling Approach for Low-Field MRI Systems", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Two-Dimensional Compressed Sensing Using the Cross-sampling Approach for Low-Field MRI Systems"}]}, "item_type_id": "5", "owner": "1", "path": ["142", "602"], "permalink_uri": "http://hdl.handle.net/2241/00122167", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-09-25"}, "publish_date": "2014-09-25", "publish_status": "0", "recid": "31416", "relation": {}, "relation_version_is_last": true, "title": ["Two-Dimensional Compressed Sensing Using the Cross-sampling Approach for Low-Field MRI Systems"], "weko_shared_id": 5}
Two-Dimensional Compressed Sensing Using the Cross-sampling Approach for Low-Field MRI Systems
http://hdl.handle.net/2241/00122167
http://hdl.handle.net/2241/00122167488a68d0-8693-4615-b449-bea0a82a9efc
名前 / ファイル | ライセンス | アクション |
---|---|---|
IEEETMI_33-9 (537.3 kB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-09-25 | |||||
タイトル | ||||||
タイトル | Two-Dimensional Compressed Sensing Using the Cross-sampling Approach for Low-Field MRI Systems | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Tamada, D.
× Tamada, D.× Kose, K. |
|||||
著者別名 |
玉田, 大輝
× 玉田, 大輝× 巨瀬, 勝美 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A compressed sensing method using a cross sampling and self-calibrated off-resonance correction is proposed. Estimation of the magnetic field inhomogeneity based on image registration enables the off-resonance correction with no additional radio-frequency pulses or acquisitions. In addition to this advantage, a fast and straightforward calculation was achieved by using the first-order components of the magnetic field inhomogeneity. Imaging experiments using a phantom and a chemically fixed mouse demonstrated practical benefits in improving blurring and artifacts in magnetic resonance images in low field magnetic resonance imaging systems. | |||||
書誌情報 |
IEEE Transactions on Medical Imaging 巻 33, 号 9, p. 1905-1912, 発行日 2014-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0278-0062 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA10634023 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 24879645 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TMI.2014.2326864 | |||||
権利 | ||||||
権利情報 | © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | |||||
著者版フラグ | ||||||
値 | author | |||||
出版者 | ||||||
出版者 | IEEE |