WEKO3
アイテム
{"_buckets": {"deposit": "377e827d-3308-4d31-b61a-d2cd4af792ce"}, "_deposit": {"id": "27686", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "27686"}, "status": "published"}, "_oai": {"id": "oai:tsukuba.repo.nii.ac.jp:00027686", "sets": ["531", "1808"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2012-10", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "501", "bibliographicPageStart": "491", "bibliographicVolumeNumber": "98", "bibliographic_titles": [{"bibliographic_title": "Applied energy"}]}]}, "item_5_creator_3": {"attribute_name": "著者別名", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "宋, 春風"}], "nameIdentifiers": [{"nameIdentifier": "95801", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北村, 豊"}], "nameIdentifiers": [{"nameIdentifier": "158", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "20246672", "nameIdentifierScheme": "e-Rad", "nameIdentifierURI": "https://nrid.nii.ac.jp/ja/nrid/1000020246672"}, {"nameIdentifier": "0000001381", "nameIdentifierScheme": "筑波大学研究者総覧", "nameIdentifierURI": "http://trios.tsukuba.ac.jp/researcher/0000001381"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In previous research, a cryogenic system based on Stirling coolers has been developed. In this work, the novel system was applied on CO2 capture from post-combustion flue gas and different process parameters (i.e. flow rate of feed gas, temperature of Stirling cooler and operating condition) were investigated to obtain the optimal performance (CO2 recovery and energy consumption). From the extensive experiments, it was concluded that the cryogenic system could realize CO2 capture without solvent and pressure drop condition. Meanwhile, the results showed that for post-combustion, the novel SC system can capture above 80% CO2 from flue gas with 3.4 MJ/kg CO2.", "subitem_description_type": "Abstract"}]}, "item_5_identifier_34": {"attribute_name": "URI", "attribute_value_mlt": [{"subitem_identifier_type": "HDL", "subitem_identifier_uri": "http://hdl.handle.net/2241/117620"}]}, "item_5_publisher_27": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Elsevier"}]}, "item_5_relation_11": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1016/j.apenergy.2012.04.013", "subitem_relation_type_select": "DOI"}}]}, "item_5_rights_12": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2012 Elsevier Ltd.\nNOTICE: this is the author\u0027s version of a work that was accepted for publication in Applied energy. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Applied energy, Vol.98, Pages:491-501. doi: 10.1016/j.apenergy.2012.04.013."}]}, "item_5_select_15": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_7": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0306-2619", "subitem_source_identifier_type": "ISSN"}]}, "item_5_source_id_9": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00543227", "subitem_source_identifier_type": "NCID"}]}, "item_5_subject_20": {"attribute_name": "NIIサブジェクト", "attribute_value_mlt": [{"subitem_subject": "環境学", "subitem_subject_scheme": "Other"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Song, Chun Feng"}], "nameIdentifiers": [{"nameIdentifier": "95798", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kitamura, Yutaka"}], "nameIdentifiers": [{"nameIdentifier": "95799", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Li, Shu Hong"}], "nameIdentifiers": [{"nameIdentifier": "95800", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2013-12-25"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "AE_98.pdf", "filesize": [{"value": "781.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 781300.0, "url": {"label": "AE_98.pdf", "url": "https://tsukuba.repo.nii.ac.jp/record/27686/files/AE_98.pdf"}, "version_id": "f7475e25-2f28-47fe-bf55-bfe214b1135c"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Evaluation of Stirling cooler system for cryogenic CO2 capture", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Evaluation of Stirling cooler system for cryogenic CO2 capture"}]}, "item_type_id": "5", "owner": "1", "path": ["531", "1808"], "permalink_uri": "http://hdl.handle.net/2241/117620", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-09-28"}, "publish_date": "2012-09-28", "publish_status": "0", "recid": "27686", "relation": {}, "relation_version_is_last": true, "title": ["Evaluation of Stirling cooler system for cryogenic CO2 capture"], "weko_shared_id": 5}
Evaluation of Stirling cooler system for cryogenic CO2 capture
http://hdl.handle.net/2241/117620
http://hdl.handle.net/2241/117620e9738077-388a-4141-9827-72a39c5cdeaa
名前 / ファイル | ライセンス | アクション |
---|---|---|
AE_98.pdf (781.3 kB)
|
|
Item type | Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-09-28 | |||||
タイトル | ||||||
タイトル | Evaluation of Stirling cooler system for cryogenic CO2 capture | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Song, Chun Feng
× Song, Chun Feng× Kitamura, Yutaka× Li, Shu Hong |
|||||
著者別名 |
宋, 春風
× 宋, 春風× 北村, 豊 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In previous research, a cryogenic system based on Stirling coolers has been developed. In this work, the novel system was applied on CO2 capture from post-combustion flue gas and different process parameters (i.e. flow rate of feed gas, temperature of Stirling cooler and operating condition) were investigated to obtain the optimal performance (CO2 recovery and energy consumption). From the extensive experiments, it was concluded that the cryogenic system could realize CO2 capture without solvent and pressure drop condition. Meanwhile, the results showed that for post-combustion, the novel SC system can capture above 80% CO2 from flue gas with 3.4 MJ/kg CO2. | |||||
書誌情報 |
Applied energy 巻 98, p. 491-501, 発行日 2012-10 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0306-2619 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA00543227 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.apenergy.2012.04.013 | |||||
権利 | ||||||
権利情報 | © 2012 Elsevier Ltd. NOTICE: this is the author's version of a work that was accepted for publication in Applied energy. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Applied energy, Vol.98, Pages:491-501. doi: 10.1016/j.apenergy.2012.04.013. |
|||||
著者版フラグ | ||||||
値 | author | |||||
出版者 | ||||||
出版者 | Elsevier | |||||
URI | ||||||
識別子 | http://hdl.handle.net/2241/117620 | |||||
識別子タイプ | HDL |